Limit switch
A roller-lever switch for detecting when a moving part reaches a stop.
Modeled roller-lever height: approximately 14.8 mm above the component-side PCB surface in the illustrated position. Allow space for the roller and lever through their full stroke.
Usage
Choose Add device → Limit switch. Press the lever until it clicks, then release it. Place the stop so it trips the lever before the end of travel. The normally closed contact changes the sense of CTS compared with the pushbutton.
Protocol
USB contact input. Read the clear-to-send signal (CTS) to get the switch state.
| Operation | Request or signal | Result |
|---|---|---|
| Open with Web Serial | port.open({baudRate: 9600, flowControl: "none"}) | Opens the port for polling. |
| Set DTR low | port.setSignals({dataTerminalReady: false}) | Configures the serial control line. |
| Read with Web Serial | (await port.getSignals()).clearToSend | true = Released, false = Pressed. |
| Read with WebUSB | Vendor IN request to the device: 0x95, value 0x0706, index 0, length 2. | Bit 0 of byte 0: 0 = Released, 1 = Pressed. |
Use either the Web Serial or WebUSB path. The console polls every 10 ms and displays a change after 20 ms of stable readings.
Mounting
The PCB measures 24 × 30 mm, with 4 × Ø2.2 mm clearance holes for M2 screws. The centre-to-centre spacing is 19 × 25 mm. Orient the component side with the J1 USB-C port at the bottom. Measure right and up from the lower-left corner of the PCB in the component-side view. The hole centres are at X = 2.5, 21.5 mm and Y = 2.5, 27.5 mm.